We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Revvity The Alphalisa® Immunoassay Kit For Human
Revvity Formats: - REVPFZ (Additional S&H Or Hazmat Fees May Apply)
Our 100 assay point kit allows you to run 100 wells in 96-well format, using a 100 µL reaction volume (10 µL of sample).Our 500 assay point kit allows you to run 500 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).Our 5,000 assay point kit allows you to run 5,000 wells in 96-well or 384-well format, using a 50 µL reaction volume (5 µL of sample).Revvity AlphaLISA features: - REVPFZ (Additional S&H Or Hazmat Fees May Apply)
No-wash steps, no separation stepsELISA alternative technologySensitive detectionBroad sample compatibilitySmall sample volumeResults in less than 3 hoursHalf the time of an ELISA assayRevvity AlphaLISA technology allows the detection of molecules of interest in buffer, cell culture media, serum and plasma in a highly sensitive, quantitative, reproducible and user-friendly mode. In an AlphaLISA assay, a Biotinylated Anti-Analyte Antibody binds to the Streptavidin-coated Alpha Donor beads, while another Anti-Analyte Antibody is conjugated to AlphaLISA Acceptor beads. In the presence of the analyte, the beads come into close proximity. The excitation of the Donor beads provokes the release of singlet oxygen molecules that triggers a cascade of energy transfer in the Acceptor beads, resulting in a sharp peak of light emission at 615 nm. - REVPFZ (Additional S&H Or Hazmat Fees May Apply)
Revvity N-terminal prohormone of brain natriuretic peptide (NT-proBNP) is a 76-amino acid sequence cleaved from the N-terminal end of brain natriuretic peptide. NT-proBNP is an inactive protein that is used for the screening for acute congestive heart failure. Serum and plasma levels of NT-proBNP varies between individuals and generally increase with age. The physiological role of NT-proBNP is not clear, while the function of BNP is to protect the cardiovascular system from volume overload by regulating salt and water homeostasis. NT-proBNP has a longer biological half-life and therefore is the preferred biomarker for detection and analysis. - REVPFZ (Additional S&H Or Hazmat Fees May Apply)
| SKU | REVPFZ-AL3114C |
|---|---|
| Supplier Part Number | AL3114C |
| UM | EA |
| UNSPSC | 41122100 |
| Manufacturer | Revvity |
| CountryOfOrigin | United States |
| ProductLine | REVPFZ |
| Qty | 1 |
| MinOrderQty | 1 |
| Weight | 7.000000 |
| Lead Time | 6 |
| Hazardous | N |
| Energy Star | No |
| Green | No |
| Controlled | N |