We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn about our cookie policy.
Labconco 4 Ft Airo Hood, No Service Fixtures, One Gfci Duplex, Extra Deep, 115v
List Price
$25,116.00
Your Price
$25,116.00
Labconco 4 Ft Airo Hood, No Service Fixtures, One Gfci Duplex, Extra Deep, 115v - SPCM (Additional S&H or Hazmat Fees May Apply)
NETA PART:
SPCM-196-18665-E1
MFG.PART:
196-18665-E1
UNSPSC:
41103502
Manufacturer:
Spectrum Chemical
Labconco The protector echo filtered fume hood requires no ducting and is available in 4, 5, 6 and 8 ft widths. Neutrodine® unisorb filtration technology offers comprehensive molecular filtration. Eguard® communication software offers real-time monitoring on the users phone or computer. From a remote location, data such as usage authorization, filter saturation detection, sash position and temperature may be observed and managed.
erlab-proven neutrodine® unisorb filters are the heart of gfh filtration technology. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration. Filters are sold separately.
features (all models)
• eco-foil™ air foil with aerodynamic clean-sweep™ airflow openings
• cord-keeper™ slots on left and right side of air foil
• removable front and side panels, and front and interior service access panels for access to plumbing and electrical wiring
• by-pass airflow design
• glacier white powder-coated steel exterior
• chemical-resistant, fiberglass-reinforced, composite panel liner
• pre-wired vapor-proof led lights for up to 63 foot candles rated for 50, 000 hours
• eguard2 software communication
• factory-installed command module, fan button and light button
• roughing prefilter
• built-in exhaust fans to maintain 60 fpm face velocity at 16 in. Sash opening height
• sound pressure of <60 db(a) with sash at operating height and <48 db(a) with sash closed
• sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature
• audible/visual alarms for breakthrough detection, temperature 40° c (104° f), fan failure and high sash position opening. At 60°c (140°f), all fans stop
• single piece, tempered safety glass vertical-rising sash with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with airflow openings. Sash stop at 16 in. Sash opening height on 4 ft models and 13 in. Sash opening height on 3 ft models. Sash opens to 26 in. High for loading
• factory-prepared for up to two electrical duplex receptacles and four service fixtures
• 28.5 in. High sightline from the work surface and header panel
• power cord with plug
fixtured models may feature
• one pre-wired gfci electrical duplex receptacle on lower right side
required accessories (not included)
• neutrodine® unisorb filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood
• work surface
• base cabinet or stand
options available include
• HEPA filter
• region-specific electrical plug configurations
• service fixtures
compliance
• sefa 9, dhiii
• sefa 8, cabinet surface finish tests
• modified ashrae 110
• ansi z9.5-2011
• afnor nf-x 15-211
• astm e84-09c
• ul standard 61010-1
• can/csa c22.2 no. 61010-1
specifications
• airflow type: bypass
• product subcategory: general chemistry
• air foil type: eco-foil
• blower requirements: integral blower included
• conformance: afnor nf-x, ansi z9.5, astm e84, can/csa c22.2, modified ashrae 110, sefa 9, ul 61010
• enclosure height: 54.2 in.
• lighting: led
• power cord & plug: 11.75 ft power cord with plug
• sash type: cable and pulley
• service fixtures: 0
• style: benchtop
- SPCM (Additional S&H Or Hazmat Fees May Apply)
erlab-proven neutrodine® unisorb filters are the heart of gfh filtration technology. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration. Filters are sold separately.
features (all models)
• eco-foil™ air foil with aerodynamic clean-sweep™ airflow openings
• cord-keeper™ slots on left and right side of air foil
• removable front and side panels, and front and interior service access panels for access to plumbing and electrical wiring
• by-pass airflow design
• glacier white powder-coated steel exterior
• chemical-resistant, fiberglass-reinforced, composite panel liner
• pre-wired vapor-proof led lights for up to 63 foot candles rated for 50, 000 hours
• eguard2 software communication
• factory-installed command module, fan button and light button
• roughing prefilter
• built-in exhaust fans to maintain 60 fpm face velocity at 16 in. Sash opening height
• sound pressure of <60 db(a) with sash at operating height and <48 db(a) with sash closed
• sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature
• audible/visual alarms for breakthrough detection, temperature 40° c (104° f), fan failure and high sash position opening. At 60°c (140°f), all fans stop
• single piece, tempered safety glass vertical-rising sash with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with airflow openings. Sash stop at 16 in. Sash opening height on 4 ft models and 13 in. Sash opening height on 3 ft models. Sash opens to 26 in. High for loading
• factory-prepared for up to two electrical duplex receptacles and four service fixtures
• 28.5 in. High sightline from the work surface and header panel
• power cord with plug
fixtured models may feature
• one pre-wired gfci electrical duplex receptacle on lower right side
required accessories (not included)
• neutrodine® unisorb filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood
• work surface
• base cabinet or stand
options available include
• HEPA filter
• region-specific electrical plug configurations
• service fixtures
compliance
• sefa 9, dhiii
• sefa 8, cabinet surface finish tests
• modified ashrae 110
• ansi z9.5-2011
• afnor nf-x 15-211
• astm e84-09c
• ul standard 61010-1
• can/csa c22.2 no. 61010-1
specifications
• airflow type: bypass
• product subcategory: general chemistry
• air foil type: eco-foil
• blower requirements: integral blower included
• conformance: afnor nf-x, ansi z9.5, astm e84, can/csa c22.2, modified ashrae 110, sefa 9, ul 61010
• enclosure height: 54.2 in.
• lighting: led
• power cord & plug: 11.75 ft power cord with plug
• sash type: cable and pulley
• service fixtures: 0
• style: benchtop
- SPCM (Additional S&H Or Hazmat Fees May Apply)
| SKU | SPCM-196-18665-E1 |
|---|---|
| Supplier Part Number | 196-18665-E1 |
| UM | EA |
| UNSPSC | 41103502 |
| Manufacturer | Spectrum Chemical |
| ProductLine | SPCM |
| Qty | 1 |
| MinOrderQty | 1 |
| Weight | 7.000000 |
| Lead Time | 5 |
| Hazardous | N |
| Energy Star | No |
| Green | No |
| Controlled | N |